Technique 4: Using Data Log breakpointĭata Log breakpoint is a powerful debugging feature for ARM Cortex-M3 and M4 devices. That makes is useful for measuring time, especially for ARM Cortex-M0/M0+ MCUs which do not have the CYCLECOUNTER register. The ARM Cortex-M SystickTimer count is stopped while the CPU is not running. Therefore, you should store the count value to a variable.

#Iar arm 7.4 crack code

If you use the time of an actual function, the Timer count can be reset by an interrupt and therefore we recommend using the timer only for measurements. While the code execution is halted at a breakpoint, the timer count can be running.

iar arm 7.4 crack

The result is as follows: cnt1:370 cnt2:740 diff:370 If the pre-scaler is 10, each 10 clock source cycle, the timer counter will be counted up or down. If the Clock source is the same as the CPU clock, the pre-scaler is 1000, the CPU clock is 100MHz and the Timer count difference is 100, then you can get 0.001 sec, so 1 ms as the elapsed time.

  • Timer configurations are different for each MCU, but you can use a common approachįirst, you need to consider the clock source and pre-scaler.
  • You can also measure the elapsed time by reading the count timer. Often, you use the timer to get an interrupt by count-up or countdown timers. The timer is an important feature for the MCU to execute periodical processes. It is recommended not to measure only one or two instructions, but instead ten or more instructions to get more precise data. If you need to get the actual time, divide by the CPU clock. The CYCLECOUNTER can be different in pipeline or cache conditions. The CYCLECOUNTER is easy to use and provides precise measurements. If you use another debugging probe and CYCLECOUNTER values are not updated, try setting the CYCCNTENA bit in the DWT Control register (DWT_CTRL.CYCCNTEN) which can be found in the Data Watchpoint and Trace register window. If you use I-jet, CYCLECOUNTER will be enabled.

    #Iar arm 7.4 crack how to

    How to use CYCLECOUNTERĬYCLECOUNTER is the elapsed cycle from start, and CCSTEP is the elapsed cycle from the last displayed timing.īy clicking Step Over, you increase the CYCLECOUNTER and the difference is shown as CCSTEP.Ĥ24(Current CYCLECOUNTER) – 416(Previous CYCLECOUNTER) = 8(Current CCSTEP)ĬYCLECOUNTER is provided by ARM Cortex-M3 MCUs but disabled in IAR Embedded Workbench for ARM as a default. IAR Embedded Workbench for ARM expands the functionality of CYCLECOUNTER so that you can easily see the differences of CYCLECOUNTER using the CCSTEP register. For example, if the CPU is running at 100MHz, you can divide by 100,000,000 to get the number of seconds passed.

    iar arm 7.4 crack

    Getting CYCLECOUNTER of two code points, and using the CPU clock, you can calculate the actual execution time. ARM Cortex-M3/4/7 devices provide a register called CYCLECOUNTER. Recent MCUs often have a register to display elapsed cycles. Technique 2: Using CycleCount register of the MCU You can also, for example, loop the target function a thousand times and measure the before and after time to get the elapsed time. This technique is not suitable for precise measurement, but it is very easy to use. Time of Execution, corresponding source code and the count of the call are displayed. The output of the execution can be seen in the Debug Log window: This code is a timer interrupt handler, which is triggered every one second. You will see the breakpoint marked with L: Right click the code for which you would like to know the executed time, and select Toggle Breakpoint (Log). If you only need a rough measurement, you can use a Log Breakpoint. When the code where the log breakpoint has been set is executed, the computer time will be displayed to the debug log window. In this article, we introduce three basic techniques and a couple of more advanced techniques to measure the elapsed time with an ARM Cortex-M3/M4/M33/M7 device and IAR Embedded Workbench for ARM.

    iar arm 7.4 crack

    However, you can measure the elapsed time easily and more precisely by using functionality available in your MCU and development tools.

    iar arm 7.4 crack

    It is popular to use GPIO pins and oscilloscopes to measure the timing, and that is of course a valid and realistic approach.